KEYPOWER GENERATOR TESTER SPECIFICATIONS
|
|
Measurement
|
Range
|
Accuracy
|
Resolution
|
Overload
|
|
Voltage (V)
|
10.0~500.0V
|
± (0.4% reading+0.1%range)
|
0.1V
|
600V
|
|
Current (A)
|
0.030~5.000A
|
± (0.4% reading+0.1%range)
|
0.001A
|
6A
|
|
Power
|
According to volt range
& current range
|
Power factor =1.0
|
<200W 0.1W
|
|
|
± (0.4% reading+0.1% range)
|
≥200W 1W
|
|
Power factor =0.5
|
≥2kW 10W
|
|
± (0.8% reading+0.2% range)
|
|
|
Power Factor
|
0.20~1.00
|
±0.02
|
0.001
|
|
|
Frequency
|
45~65Hz
|
±0.2Hz
|
0.01Hz
|
|
|
|
Running Time
|
99h59m
|
±2min/hour
|
1 minute
|
|
|
Energy
(kWh)
|
99999kWh
|
Power factor= 1.0
|
0.001kwh
|
|
|
± (0.4% reading+0.1% range)
|
|
Power factor=0.5
|
|
± (0.8% reading+0.2% range)
|
|
Harmonic Analysis
(%)
|
2-50 times
and total harmonic
|
|
|
|
|
Models You Can Choose
|
Model
|
Testing
capacity
|
Type
of
load
|
Duty
|
Cooling
system
|
Phase
|
Rated
Testing
Voltage
|
Rated
Frequency
|
Dimensions
(L*W*H)
(mm)
|
Weight
(kg)
|
KPLB-100
|
0 - 100 kw
|
Resistive
or
Reactive,
PF =
1.0 or 0.8
|
Continuous
|
Industrial
grade
axial fan
|
Available
at both
single
and
three
phase
|
110-480
VAC
|
50/60 Hz
|
960*1060*1400
|
350
|
KPLB-200
|
0 - 200 kw
|
1560*1310*1650
|
837
|
KPLB-300
|
0 - 300 kw
|
1690*1440*1750
|
1083
|
KPLB-400
|
0 - 400 kw
|
1900*1600*1900
|
1200
|
KPLB-500
|
0 - 500 kw
|
1900*1600*1900
|
1400
|
KPLB-600
|
0 - 600 kw
|
2100*1730*2000
|
1550
|
KPLB-700
|
0 - 700 kw
|
2100*1730*2000
|
1650
|
KPLB-800
|
0 - 800 kw
|
2400*2330*2100
|
1750
|
KPLB-1000
|
0 - 1000 kw
|
2400*2330*2200
|
2150
|
KPLB-2000
|
0 - 2000 kw
|
20 ft container
|
6000
|
KPLB-5000
|
0 - 5000 kw
|
40HC container
|
16000
|
KEYPOWER Load Bank Technical Specifications
1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade nickel-chromium alloys resistive wire covered by 3-year warranty.
2. Rated testing voltage: AC 3P4W, 110-480 VAC 50/60HZ.
3. Cooling mode: forced air-cooled, fans mounted on the side of the load bank blow horizontally. External utility power or internal tested power supply for fans.
4. Working mode: load step control
Total testing capacity ranges from 0kw to the 200kW consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the 200kW, any load combination is achievable. Load step resolution is 10kw.
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
contactors.
switches, knobs and indicators.
circuit breakers.
intermediate relays.
terminal blocks.
6. Parameter measuring accuracy grade: 0.5.
7. Load control accuracy: ±3%.
8. Load bank protections: over heating protection, cooling fans failure protection and over load protection with alarm.
9. Control mode: two control modes available: a) Local manual control; b) Optional: Manual control via a remote control panel (max control distance is 20m).
10. Parameter display and measurement: Control panel contains a
Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: a professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing).
11. Operating environment: Altitude: ≤1000m above sea level. Ambient temp: -10℃~+40℃ Relative humidity: ≤80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.