KEYPOWER 500kW Resistive Load Bank For Generator TestingModel: KPLB-500 Testing capacity: 0 – 500 kw Type of load: Resistive, PF = 1.0 Duty:Continuous Cooling system: Industrial grade axial fan Phase: Available at both single and three phase Rated testing voltage: 110-480 VAC Rated Frequency: 50/60 Hz Specifications 100-2000KW Load Bank for Generator Load Test: 1.Premium components 2.Durable and reliable 3.Easy to transport 1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide. 2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 4. Working mode: Load step control Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 5. Load bank features world-famous components to ensure reliable performance and longer service life including: SCHNEIDER contactors. Siemens switches, knobs and indicators. ABB Circuit breakers. OMRON intermediate relays. PHOENIX terminal blocks. 6. Parameter measuring accuracy grade: 0.3 7. Load control accuracy: ± 5%. 8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 9. Control mode: Two control modes available: A)Local manual control; B)Optional: Manual control via a remote control panel (max control distance is 30m). 10. Parameter display and measurement: Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). ” 11. Operating environment: Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃ Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment. Any question, please contact me directly.
-
KEYPOWER 500kW Resistive Load Bank For Generator TestingModel: KPLB-500 Testing capacity: 0 – 500 kw Type of load: Resistive, PF = 1.0 Duty:Continuous Cooling system: Industrial grade axial fan Phase: Available at both single and three phase Rated testing voltage: 110-480 VAC Rated Frequency: 50/60 Hz Specifications 100-2000KW Load Bank for Generator Load Test: 1.Premium components 2.Durable and reliable 3.Easy to transport 1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide. 2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 4. Working mode: Load step control Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 5. Load bank features world-famous components to ensure reliable performance and longer service life including: SCHNEIDER contactors. Siemens switches, knobs and indicators. ABB Circuit breakers. OMRON intermediate relays. PHOENIX terminal blocks. 6. Parameter measuring accuracy grade: 0.3 7. Load control accuracy: ± 5%. 8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 9. Control mode: Two control modes available: A)Local manual control; B)Optional: Manual control via a remote control panel (max control distance is 30m). 10. Parameter display and measurement: Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). ” 11. Operating environment: Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃ Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment. Any question, please contact me directly.