    2020-09-11

    Piston spring of oil supply pump breaks The engine flamed out during operation and could not be started.After unscrewing the air release screw, it is found that the low pressure oil chamber of the fuel injection pump has no or very little fuel. Pump oil with the hand pump until the whole low pressure oil chamber is filled with oil, exhaust the air, restart the engine, and the engine returns to nor...

    read more
  • 柴油发电机常见的故障现象6
    柴油发电机常见的故障现象6
    2020-09-04

    Low pressure oil supply is not smooth Diesel engine from the fuel tank to the fuel pump inlet cavity in between, back to belong to the low pressure oil pipe line, when the pipe joint, washer and tubing oil due to damage, will make the air into the oil produces gas resistance, leading to poor drainage, difficulty in starting and accelerating engine slow fault phenomena, such as serious shut down au...

    read more
  • Common failure phenomena of diesel generators 5
    Common failure phenomena of diesel generators 5
    2020-08-31

    Look at the phenomenon, check the circuit For electronically controlled diesel engines, the following two conditions will also lead to diesel engine power shortage.Thermal protection: If the temperature of the electronically controlled diesel engine is abnormal, the temperature of the coolant may be too high;High intake temperature;Fuel temperature is too high;Coolant temperature sensor circuit fa...

    read more
  • Common malfunction of diesel generator 4
    Common malfunction of diesel generator 4
    2020-08-27

    Look at the pressure, check for leaks Pressure gauge can be used to measure the cylinder pressure, find out the poor sealing cylinder.Reasons for poor cylinder sealing: valve clearance or clearance is too small, piston and cylinder sleeve and piston ring end face clearance is too large, ring groove carbon.In the diesel engine work, if close to the air filter can hear the "hiss, hiss" blowing sound...

    read more
  • Common malfunction of diesel generator 3
    Common malfunction of diesel generator 3
    2020-08-24

    Water temperature, check cooling If the cooling system temperature of the diesel engine is too high (more than 100℃) during operation, it can indicate that the scale in the cooling water cavity of the diesel engine is too thick or that relevant components of the cooling system (thermostat, water pump, fan, etc.) are inefficient or fail. Look at the distribution and check the phase After a long per...

    read more
  • Common malfunction of diesel generator 2
    Common malfunction of diesel generator 2
    2020-08-21

    Look at the carbon, check the working condition The carbon accumulation in the exhaust port of diesel engine is black gray, and the surface is covered with a layer of white frost. The carbon accumulation layer is very thin, which indicates that the diesel engine works well.The charcoal color is black and not wet, indicating that the diesel engine burns oil slightly.The thick carbon accumulation in...

    read more
  • Common malfunction of diesel generator 1
    Common malfunction of diesel generator 1
    2020-08-20

    Look up and down smoke, check wear and tear When the diesel engine is working, open the oil cap. If a stream of smoke comes out from the cap, weigh the smoke.Serious lower smoke phenomenon, indicating that the piston, cylinder liner, piston ring and other components are seriously worn.Open the valve chamber cover, if there is a trace of blue or white smoke from the valve root (valve face), weigh t...

    read more
  • How to excite the higher performance of the generator?
    How to excite the higher performance of the generator?
    2020-08-17

    A, timing, The factors that influence the frequency of grease replacement are very complex and generally include temperature, service continuity, amount of grease injected, bearing size and speed, sealing effectiveness, and suitability of the grease for particular applications.Therefore, deciding when and how often to replace the grease is not a simple matter. Under normal circumstances, continuou...

    read more
<< 1 2 3 4 5 6 7 8 9 10 >>

A total of 15 pages

we are expert in generator set!

Want To View More Works Done By Our Team.
Get a Quote

Focusing on the field of new energy power generation in 20 years, products and services cover more than 50 countries in the world. The R & D team collects top experts in various fields, and is committed to providing the world's first class PV power plant solutions.

 

Chat now

Live Chat

We will contact you as soon as possible!