banner
New Products

View :

  • 30kva diesel generator
    Keypower 30 KVA FAWDE Diesel Generators
    DIESEL GENERATOR SPECIFICATIONS 1. Powered by reliable engines 2. Branded alternator 3. Open type, silent type  generator 4. ISO, CE certified GENERATOR SPECS: Rated output: 2 to 2,000kW/2 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz ENGINE: Brands: Cummins, Perkins,  Deutz, Doosan, Mitsubishi, Kubota, Yanmar or other reliable Chinese engines such as Fawde and Laidong. Cooling method: closed water-cooled or air-cooled Starting method: electric start or recoil start Rated speed: 1,500/1,800/3,000/3,600rpm Noise level: 56 to 75dB, 7 meters away ALTERNATOR: Brands: Stamford, Leroy Somer, Mecc Alte and Keypower brushless alternator Rated output: 8 to 2,000kW/10 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz Phase: 3-phase, 4-wire or 1-phase, 2-wire Connection: y or other type connection Rated speed: 1,500/1,800rpm Excitation: harmonic excitation or phase compound or brushless Voltage regulation: AVR automatic 1.0% voltage regulation in static conditions (maximum) Protection class: IP23 Control panel: Deepsea, ComAp, Keypower THE PANEL IS PROVIDED WITH: Standard engine instrumentation Voltmeter with selector switch Ammeter with selector switch Frequency meter Current transformers MCB of suitable rating with overload and short-circuit protection Optional with AMF control panel or with ATS (automatic transfer switch) APPLICATIONS: With advanced reasonable structure, high efficiency, low vibration and noise, smooth running, high reliability, easy handling, KEYPOWER generators are widely used in national defense, telecommunications, construction site, commercial buildings, industrial and mining sites, oil fields, roads, ports, villas, banks, hospitals etc. ANY QUESTION, PLEASE CONTACT US DIRECTLY.
  • KEYPOWER 500kW Resistive Load Bank For Generator Testing
    Model: KPLB-500 Testing capacity: 0 – 500 kw Type of load: Resistive, PF = 1.0 Duty:Continuous Cooling system: Industrial grade axial fan Phase: Available at both single and three phase Rated testing voltage: 110-480 VAC Rated Frequency: 50/60 Hz Specifications 100-2000KW Load Bank for Generator Load Test: 1.Premium components 2.Durable and reliable 3.Easy to transport 1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide. 2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 4. Working mode: Load step control Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 5. Load bank features world-famous components to ensure reliable performance and longer service life including: SCHNEIDER contactors. Siemens switches, knobs and indicators. ABB Circuit breakers. OMRON intermediate relays. PHOENIX terminal blocks. 6.  Parameter measuring accuracy grade: 0.3 7. Load control accuracy: ± 5%. 8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 9. Control mode: Two control modes available: A)Local manual control; B)Optional: Manual control via a remote control panel (max control distance is 30m). 10. Parameter display and measurement: Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). ” 11. Operating environment: Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃ Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment. Any question, please contact me directly.
  • KEYPOWER 2400kW Resistive Load Bank For Generator Testing
    Model: KPLB-500 Testing capacity: 0 – 500 kw Type of load: Resistive, PF = 1.0 Duty:Continuous Cooling system: Industrial grade axial fan Phase: Available at both single and three phase Rated testing voltage: 110-480 VAC Rated Frequency: 50/60 Hz Specifications 100-2000KW Load Bank for Generator Load Test: 1.Premium components 2.Durable and reliable 3.Easy to transport 1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide. 2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 4. Working mode: Load step control Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 5. Load bank features world-famous components to ensure reliable performance and longer service life including: SCHNEIDER contactors. Siemens switches, knobs and indicators. ABB Circuit breakers. OMRON intermediate relays. PHOENIX terminal blocks. 6.  Parameter measuring accuracy grade: 0.3 7. Load control accuracy: ± 5%. 8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 9. Control mode: Two control modes available: A)Local manual control; B)Optional: Manual control via a remote control panel (max control distance is 30m). 10. Parameter display and measurement: Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). ” 11. Operating environment: Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃ Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment. Any question, please contact me directly.
  • 50HZ 60HZ 250kw GENERATOR SETS POWERED BY Perkins ENGINE
    DIESEL GENERATOR SPECIFICATIONS 1. Powered by reliable engines 2. Branded alternator 3. Open type, silent type  generator 4. ISO, CE certified GENERATOR SPECS: Rated output: 2 to 2,000kW/2 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz ENGINE: Brands: Cummins, Perkins,  Deutz, Doosan, Mitsubishi, Kubota, Yanmar or other reliable Chinese engines such as Fawde and Laidong. Cooling method: closed water-cooled or air-cooled Starting method: electric start or recoil start Rated speed: 1,500/1,800/3,000/3,600rpm Noise level: 56 to 75dB, 7 meters away ALTERNATOR: Brands: Stamford, Leroy Somer, Mecc Alte and Keypower brushless alternator Rated output: 8 to 2,000kW/10 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz Phase: 3-phase, 4-wire or 1-phase, 2-wire Connection: y or other type connection Rated speed: 1,500/1,800rpm Excitation: harmonic excitation or phase compound or brushless Voltage regulation: AVR automatic 1.0% voltage regulation in static conditions (maximum) Protection class: IP23 Control panel: Deepsea, ComAp, Keypower THE PANEL IS PROVIDED WITH: Standard engine instrumentation Voltmeter with selector switch Ammeter with selector switch Frequency meter Current transformers MCB of suitable rating with overload and short-circuit protection Optional with AMF control panel or with ATS (automatic transfer switch) APPLICATIONS: With advanced reasonable structure, high efficiency, low vibration and noise, smooth running, high reliability, easy handling, KEYPOWER generators are widely used in national defense, telecommunications, construction site, commercial buildings, industrial and mining sites, oil fields, roads, ports, villas, banks, hospitals etc. ANY QUESTION, PLEASE CONTACT US DIRECTLY.
<< 1 2 3 4 5 6 7 8 9 10 >>

A total of 23 pages

we are expert in generator set!

Want To View More Works Done By Our Team.
Get a Quote

Focusing on the field of new energy power generation in 20 years, products and services cover more than 50 countries in the world. The R & D team collects top experts in various fields, and is committed to providing the world's first class PV power plant solutions.

 

Chat now

Live Chat

We will contact you as soon as possible!