banner
New Products

View :

  • Load Bank Generator testing
    300kW Resistive Load Bank Air Cooled Single Phase Generator Testing
    Total testing capacity ranges from 0kw to the 300kW  consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the 300kW , any load combination is achievable. Load step resolution is 10kw.
  • KEYPOWER 2400kW Resistive Load Bank For Generator Testing
    Model: KPLB-500 Testing capacity: 0 – 500 kw Type of load: Resistive, PF = 1.0 Duty:Continuous Cooling system: Industrial grade axial fan Phase: Available at both single and three phase Rated testing voltage: 110-480 VAC Rated Frequency: 50/60 Hz Specifications 100-2000KW Load Bank for Generator Load Test: 1.Premium components 2.Durable and reliable 3.Easy to transport 1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide. 2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 4. Working mode: Load step control Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 5. Load bank features world-famous components to ensure reliable performance and longer service life including: SCHNEIDER contactors. Siemens switches, knobs and indicators. ABB Circuit breakers. OMRON intermediate relays. PHOENIX terminal blocks. 6.  Parameter measuring accuracy grade: 0.3 7. Load control accuracy: ± 5%. 8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 9. Control mode: Two control modes available: A)Local manual control; B)Optional: Manual control via a remote control panel (max control distance is 30m). 10. Parameter display and measurement: Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). ” 11. Operating environment: Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃ Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment. Any question, please contact me directly.
  • KEYPOWER 500kW Resistive Load Bank For Generator Testing
    Model: KPLB-500 Testing capacity: 0 – 500 kw Type of load: Resistive, PF = 1.0 Duty:Continuous Cooling system: Industrial grade axial fan Phase: Available at both single and three phase Rated testing voltage: 110-480 VAC Rated Frequency: 50/60 Hz Specifications 100-2000KW Load Bank for Generator Load Test: 1.Premium components 2.Durable and reliable 3.Easy to transport 1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide. 2. Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 4. Working mode: Load step control Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 5. Load bank features world-famous components to ensure reliable performance and longer service life including: SCHNEIDER contactors. Siemens switches, knobs and indicators. ABB Circuit breakers. OMRON intermediate relays. PHOENIX terminal blocks. 6.  Parameter measuring accuracy grade: 0.3 7. Load control accuracy: ± 5%. 8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 9. Control mode: Two control modes available: A)Local manual control; B)Optional: Manual control via a remote control panel (max control distance is 30m). 10. Parameter display and measurement: Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc. (Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). ” 11. Operating environment: Altitude: ≤ 3000m above sea level. Ambient temp: -10~+50 ℃ Relative humidity: ≤ 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment. Any question, please contact me directly.

A total of 1 pages

we are expert in generator set!

Want To View More Works Done By Our Team.
Get a Quote

Focusing on the field of new energy power generation in 20 years, products and services cover more than 50 countries in the world. The R & D team collects top experts in various fields, and is committed to providing the world's first class PV power plant solutions.

 

Chat now

Live Chat

We will contact you as soon as possible!